3/4” Metallic Dimensions and Flow Curves
Pro-Series Pumps
3/4” Metallic Dimensions and Flow Charts Q
E
F PD07R-XAS-PXX 3/4”METALLIC DIAPHRAGM PUMP
Air inlet 1/4 - 18 P.T.F. SAE Short 100 8 12 16 20 AIR CONSUMPTION IN SCFM 7 4 6 8 10 AIR CONSUMPTION IN LITERS / SEC
L Performance based on water 70 Performance based on water
at ambient temperature. at ambient temperature.
200 6 12
60
r
75 37.5
r 5
150
40 4 8
G 50 DIMENSIONS 25
3
100
B A- 9-9/32" (235.3 mm) F- 6" (152.4 mm) L- 3-29/32" (99.2 mm)
B- 11-1/16" (280.4 mm) G- 11-7/8" (301.2 mm) M- 3/8" (9.5 mm)
2
20
25 C- 6-1/8" (155.6 mm) H- 4-29/32" (124.2 mm) 12.5 N- 6-5/16" (159.8 mm) 4
50
D- 2" (50.8 mm) J- 5-1/2" (139.7 mm)
E- 6-23/32" (170.6 mm) K- 5/16" (8.0 mm) 1 2 liters / sec.
N 4 s.c.f.m.
0 0 0 0 0 0
4
14
12
0 2 Model 6 8 10 Material Inlet 16 Material Outlet 0 10 20 30 40 50 60
P CAPACITY IN U.S. GALLONS PER MINUTE FLOW RATE (LITERS / MIN.)
D PD07R-AAS-PXX 3/4 - 14 N.P.T.F. - 2 3/4 - 14 N.P.T.F. - 2
PD07R-BAS-PXX Rp 3/4 (3/4 - 14 BSP) Rp 3/4 (3/4 - 14 BSP)
PD07R-XAS-PXX 3/4”METALLIC DIAPHRAGM PUMP
H
10
AIR CONSUMPTION IN LITERS / SEC
.
8 12 16 20 AIR CONSUMPTION IN SCFM 4 M 6 8 NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only
100 J 70 7
K Performance based on water Performance based on water
at ambient temperature.
at ambient temperature.
200 6
C 60 12
A r
75 37.5
r 5
150
Q
E 40 4 8
50 25
100 F 3
Air inlet 1/4 - 18 P.T.F. SAE Short
Position 1 2 3 4 5 6 7 8 9 10 11 L 20 2 4
25 12.5
50
Example: PX07 R - X X S - X X X - B - X X 1
4 s.c.f.m. 2 liters / sec.
0 0 0 0 0 0
0 2 4 6 8 10 12 14 16 0 10 20 30 40 50 60
CAPACITY IN U.S. GALLONS PER MINUTE FLOW RATE (LITERS / MIN.)
G DIMENSIONS
B A- 9-9/32" (235.3 mm) F- 6" (152.4 mm) L- 3-29/32" (99.2 mm)
B- 11-1/16" (280.4 mm) G- 11-7/8" (301.2 mm) Refer to www.AROzone.com for full size flow curves.
M- 3/8" (9.5 mm)
For additional information contact
C- 6-1/8" (155.6 mm) H- 4-29/32" (124.2 mm) N- 6-5/16" (159.8 mm)
Q D- 2" (50.8 mm) J- 5-1/2" (139.7 mm) technical support at 1.800.495.0276
E E- 6-23/32" (170.6 mm) K- 5/16" (8.0 mm)
F N
Air inlet 1/4 - 18 P.T.F. SAE Short Model Material Inlet Material Outlet
L P D PD07R-AAS-PXX Ordering Position 10
3/4 - 14 N.P.T.F. - 2
3/4 - 14 N.P.T.F. - 2
PD07R-BAS-PXX Rp 3/4 (3/4 - 14 BSP) Rp 3/4 (3/4 - 14 BSP)
Specialty Code 1
H M NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only
.
J (Blank if no Specialty Code)
K A - Solenoid 120VAC G - Solenoid 12VDC ATEX/IECex
C
A DIMENSIONS B - Solenoid 12VDC H - Solenoid 24VDC ATEX/IECex
G
B A- 9-9/32" (235.3 mm) F- 6" (152.4 mm) L- 3-29/32" (99.2 mm) C - Solenoid 240VAC J - 120VAC NEC/CEC
B- 11-1/16" (280.4 mm) G- 11-7/8" (301.2 mm) M- 3/8" (9.5 mm) K - Solenoid 220VAC ATEX/IECex
C- 6-1/8" (155.6 mm) H- 4-29/32" (124.2 mm) N- 6-5/16" (159.8 mm) D - Solenoid 24VDC
D- 2" (50.8 mm) J- 5-1/2" (139.7 mm) E - 12vDC NEC/CEC N - Solenoid with no coil
E- 6-23/32" (170.6 mm) K- 5/16" (8.0 mm)
N F - 24vDC NEC/CEC 0 - Standard Valve Block
(No Solenoid)
P Model Material Inlet Material Outlet
D PD07R-AAS-PXX 3/4 - 14 N.P.T.F. - 2 3/4 - 14 N.P.T.F. - 2 Ordering Position 11
PD07R-BAS-PXX Rp 3/4 (3/4 - 14 BSP) Rp 3/4 (3/4 - 14 BSP)
H M NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only Specialty Code 2
.
J (Blank if no Specialty Code)
K E - End of stroke feedback + Leak
C Detection L - Leak Detection
A M - Leak Detection ATEX/IECex/NEC/CEC
F - End of stroke feedback
0 - No Option
G - End of Stroke ATEX/IECex/NEC/CEC
H - End of Stroke/Leak Detection
ATEX/IECex/NEC/CEC
arotechsupport@irco.com • (800) 495-0276 / PRO Series Diaphragm Pumps • AROzone.com 29