Test  Instruments





              Maximum display range and accuracy for digital multimeters and digital clamp meters and environmental meters
                 rdg(reading)                        Maximum display range        Accuracy
                 The value on the digital display,readout.  MT-1860/1820: the maximum display range is "5999".  When ACV measument using the MT-1270, the maximum display
                                              MT-1232: the maximum display range is "3999".  value is 199.9V, minimum display value is 0.01V.
                                              MT-1280/1270/1210: the maximum display range is "1999".
                                              For example of measuring resistance at MT-1232
                                               Resistance  Display
                                                                                  Example
                  dgt(dilgit)                  4000k  4.000M  The range is automatically switched so that the   The accuracy of the AC200 V reading is ±(0.8%rdg+5dgt).
              Indicates the least significant digit.  4000  4.000k  display unit is M  or k  when measuring AC100V, the accuracy reading display range is 100.9~99.15.
              It represents the error used for processing fractions when          100V±(0.8%+5dpt)
              converting from analog to digital.  40  40.00  The reading is display with three digits.  =100+(0.80+0.05) ~100-(0.80+0.05)
                                                                                  =100.9~99.15
                       SI prefixes                           USB   USB connector                 V
                          Decimal                                                                      DC voltage
            Symbol Prefixes         Units frequently used
                      Long Scale  Short Scale
              G  giga  1X1,000,000,00  1X10 9  GHz
              M  mega  1X1,000,000  1X10 6  M , MHz                                              V     AC voltage
              K  kilo  1X1,000  1X10 3  k , kV, kW,kHz
              m  milli  1/1,000  1X10 -3  mV, mA, mW, mF, mH
              µ  micro  1/1,000,000  1X10 -6  µV, µA, µW, µF, µH
              n  nano  1/1,000,000,000  1X10 -9  nA, nF, nH
              p  pico  1/1,000,000,000,000  1X10 -12  pF, pH                                     A     DC current
                                                                                                 A     AC current
                  Backlight

             MAX  Maximum/Minimum                                                                      Resistance
              MIN  value
                                                                                                 Hz    Frequency
             MAX
             HOLD  Maximum value hold
                                                                                                       Capacitance

             HOLD  Data hold
                                                                                                       Inductor check

              AP                                                                                 ÛC
             OFF  Auto power off                                                                   ÛF  Temperature ÛC/ÛF
                                                                                                       measurement

                                                                                                 ÛC    Temperature ÛC
                  Low battery                                                                          measurement
                                                                                                 Hz
             0                                                                                   Duty  Duty cycle
             ADJ  Zero-ohm adjuster

                                                                                                 REL   Relative reference
             OUT  Output terminal

                                                                                                       Continuity buzzer
           Most of                test instruments are
           approved by CE EN61010-1 CATII/                                                       CONT.  Continuity check
           CATIII test .                                                                         LED
           CAT. II    Primary circuits or equipments
                  connected to low voltage                                                             Diode test
                  facilities, such as a standard
                  wall outlet.
           CAT. III   Equipment used for                                                               Transistor hEF
                  measurement in building                                                        hFE   test
                  facilities, distribution boards,
                  and circuit breakers.
                                                                                                 LED   LED test


                                                                             Sound level
                     Hygrometer        Thermometer        Light meter                                  Battery check
                 RH                 Air              Lux                 dB  meter
   25   26   27   28   29   30   31   32   33   34   35