Page 5 - ARO隔膜泵英格索兰
P. 5

Smart Motor Design


            COMPACT SERIES PUMPS 1/4" - 3/4"




            All ARO® Comapct Series diaphragm pumps   Diaphragm Moving Right to Left  Diaphragm Moving from Left to Right
          feature an unbalanced valve design, which   A                                                        A
          eliminates valve centering and pump                              B      B
          stall-out-even under low air inlet pressures.
          “D” Valve
             Provides a positive seal.                                                                       C
             Helps insure optimum energy efficiency                       C
             while avoiding costly air “blow-by.”
             Ceramic construction insures long                                   At end of stroke:
 Find your opportunity     service life.       1)  The diaphragm pushes the right Actuator Pin   1.)  Diaphragm pushes Pin (B) and SimulShift
                                                (B) mechanically moving the SimulShift Valve
                                                                                    Valve (A) to the right.
          “SimulShift™” Valve                   (A) to the left.                  2.)  Large ends of SimulShift Valve (A) and Major
                                               2.)  Compressed air flows to the large side of the   Valve (C) are vented to exhaust pilot signal.
             Provides an ultra-positive, reliable   SimulShift Valve, pneumatically moving the
             shift signal that avoids stall-out.  valve to the position shown.    3.)  Constant compressed air supply acting on
                                                                                    the smaller areas of the SimulShift Valve and
             Provides faster pump trip-over with    3.)  Compressed air also flows to the large end   Major Valve shifts both valves to the right
             more flow.                          of the Major Air Valve (C), pneumatically   and holds them in position until the next
                                                 shifting it to the left.           cycle begins.
            Faster trip-over with less pulsation
             and superior laminar
             material flow.
















































                                                   arotechsupport@irco.com • (800) 495-0276  / PRO Series Diaphragm Pumps  •  AROzone.com    5
   1   2   3   4   5   6   7   8   9   10