Page 17 - ARO隔膜泵英格索兰
P. 17
3/4” Non-Metallic Dimensions and Flow Curves
Pro-Series Pumps
3/4” Non-Metallic Dimensions and Flow Charts
PD07P-XPS-PXX 3/4”’ NON-METALLIC DIAPHRAGM PUMP
Air inlet 1/4 - 18 P.T.F. SAE Short 8 12 16 20 AIR CONSUMPTION IN SCFM 4 6 8 10 AIR CONSUMPTION IN LITERS / SEC
100 7
R Performance based on water 70 Performance based on water
A E 200 at ambient temperature. 6 at ambient temperature.
P F 60 12
75 37.5 r
r 5
150
40 4 8
50 25
100 DIMENSIONS 3
A- 10" (254.2 mm) F- 6-1/32" (153.1 mm) L- 1-15/16" (48.9 mm)
20 2 4
25 B- 10-3/32" (256.1 mm) G- 10-29/32" (276.8 mm) M- 3/8" (9.6 mm)
12.5
50
C- 6-3/16" (157.1 mm) H- 4-29/32" (124.2 mm) N- 6-5/16" (160.5 mm)
1
2 liters / sec.
G 4 s.c.f.m. D- 2" (51.0 mm) J- 5-17/32" (140.2 mm) P- 8-7/8" (225.3 mm)
N 0 0 0 2 E- 6-3/4" (171.0 mm) 10 K- 5/16" (8.0 mm) 18 0 0 0 0 10 20 30 40 50 60 70 0
6
8
12
16
14
4
B CAPACITY IN U.S. GALLONS PER MINUTE FLOW RATE (LITERS / MIN.)
PD07P-XPS-PXX 3/4”’ NON-METALLIC DIAPHRAGM PUMP Model Material Inlet Material Outlet
AIR CONSUMPTION IN LITERS / SEC
10
8 12 16 20 AIR CONSUMPTION IN SCFM 4 6 8 PD07P-APS-PXX 3/4 - 14 N.P.T.F. - 1 3/4 - 14 N.P.T.F. - 1
100 7 PD07P-BPS-PXX Rp 3/4 (3/4 - 14 BSP) Rp 3/4 (3/4 - 14 BSP)
D Performance based on water 70 Performance based on water
at ambient temperature. at ambient temperature.
200 6 12
.
60 NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only
75 L K M 37.5 H 5 r
C r J
150
Q
40 4 8
Air inlet 1/4 - 18 P.T.F. SAE Short 25
50
100 R 3
A E
Position 1 2 3 4 5 6 7 8 9 10 11 P F 20 2 4
50 25 12.5
Example: PD07 P - X X S - X X X - B - X X 4 s.c.f.m. 1 2 liters / sec.
0 0 0 0 0 0
0 2 4 6 8 10 12 14 16 18 0 10 20 30 40 50 60 70
CAPACITY IN U.S. GALLONS PER MINUTE DIMENSIONS FLOW RATE (LITERS / MIN.)
A- 10" (254.2 mm) F- 6-1/32" (153.1 mm) L- 1-15/16" (48.9 mm)
B- 10-3/32" (256.1 mm) G- 10-29/32" (276.8 mm) M- 3/8" (9.6 mm)
Refer to www.AROzone.com for full size flow curves.
C- 6-3/16" (157.1 mm) H- 4-29/32" (124.2 mm) N- 6-5/16" (160.5 mm)
For additional information contact
G D- 2" (51.0 mm) J- 5-17/32" (140.2 mm) P- 8-7/8" (225.3 mm)
technical support at 1.800.495.0276
N E- 6-3/4" (171.0 mm) K- 5/16" (8.0 mm)
B
Air inlet 1/4 - 18 P.T.F. SAE Short Model Material Inlet Material Outlet
R PD07P-APS-PXX 3/4 - 14 N.P.T.F. - 1 3/4 - 14 N.P.T.F. - 1
Ordering Position 10
A E PD07P-BPS-PXX Rp 3/4 (3/4 - 14 BSP) Rp 3/4 (3/4 - 14 BSP)
P D F Specialty Code 1
.
NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only
(Blank if no Specialty Code)
L K M H
C J A - Solenoid 120VAC G - Solenoid 12VDC ATEX/IECex
Q
B - Solenoid 12VDC H - Solenoid 24VDC ATEX/IECex
DIMENSIONS J - 120VAC NEC/CEC
C - Solenoid 240VAC
A- 10" (254.2 mm) F- 6-1/32" (153.1 mm) L- 1-15/16" (48.9 mm) K - Solenoid 220VAC ATEX/IECex
B- 10-3/32" (256.1 mm) G- 10-29/32" (276.8 mm) M- 3/8" (9.6 mm) D - Solenoid 24VDC
C- 6-3/16" (157.1 mm) H- 4-29/32" (124.2 mm) N- 6-5/16" (160.5 mm) E - 12vDC NEC/CEC N - Solenoid with no coil
G D- 2" (51.0 mm) J- 5-17/32" (140.2 mm) P- 8-7/8" (225.3 mm) F - 24vDC NEC/CEC 0 - Standard Valve Block
N E- 6-3/4" (171.0 mm) K- 5/16" (8.0 mm) (No Solenoid)
B
Model Material Inlet Material Outlet Ordering Position 11
PD07P-APS-PXX 3/4 - 14 N.P.T.F. - 1 3/4 - 14 N.P.T.F. - 1
PD07P-BPS-PXX Rp 3/4 (3/4 - 14 BSP) Rp 3/4 (3/4 - 14 BSP) Specialty Code 2
D (Blank if no Specialty Code)
.
NOTE: Dimensions are shown in inches and (mm) and are supplied for reference only
L K M H E - End of stroke feedback + Leak L - Leak Detection
C J Detection
Q F - End of stroke feedback M - Leak Detection ATEX/IECex/NEC/CEC
0 - No Option
G - End of Stroke ATEX/IECex/NEC/CEC
H - End of Stroke/Leak Detection
ATEX/IECex/NEC/CEC
arotechsupport@irco.com • (800) 495-0276 / PRO Series Diaphragm Pumps • AROzone.com 17