Page 40 - EclipseTools_CAT2017_Full
P. 40
MT-4611 Combustible Gas Detector
Sound & Light Alarm, Quick-response Sensor
• Quickly identifies & pinpoints gas leaks, provides visible
& audible alarm.
• Detection at 10% ~ 40% lower explosion limited.
• Adjustable sensitivity setting helps precisely locate leaks.
• Rugged ergonomic & easy-to-use design.
• 35cm flexible probe allows location and detection of leak
in hard-to-reach and confined spaces.
Specification
Sound and LED light alarm Measuring distance 1 meter, beep about 65dB TEST INSTRUMENTS
Resolution 50 ppm (methane)
Test range 10%—40% LEL
Response time < 2S (40% LEL)
Sensor Catalytic combustion
Low battery indicate <5V
Operation environment 10~90%RH, 0°C~50°C (no condense)
Storage environment 10~70%RH, -10°C~60°C (no condense)
Power source 1.5V / AA battery x 4 (not included)
Weight 290 g (not including battery)
Meter, 200x75x50mm / 7.9 x 3.0 x2.0″,
Dimension (L×W×D)(mm/inch)
flexible probe, Ø8x350mm / Ø0.3 x 13.8″
Accessory Storage bag
Individual packing Double blister
MT-4612 Infrared Thermometer
Non-Contact Measurement, Fast Response,
• Dual laser for accurately aiming with fast (500 ms) response time
• Ergonomic design and rugged construction
• Extra functions: unit selection, backlight, auto power off, low battery indication,
Data hold, Max./Min./average/difference record, high/low temperature alarm
Specification
Temperature Range -50°C~580°C(-58°F ~1076°F)
Accuracy ±2°C or ±2%°C
Distance Spot Ratio 16:1
Emissivity 0.1~1.0
Laser class Class II , <1mW
Response time & 500ms / 8-14μm
Wavelength
Repeatability ±1°C or ±1%°C
Resolution 0.1°C
Unit selection C° / F°
Data memory 9 memories
Laser target point Dual Laser / can be selected on / off Air conditioning Ice chest
Storage temperature -20-50°C(-4-122°F)
Operating temperature 0~50°C, 10~95%RH
Power source 6F22(9V) (not included)
Weight 204g (not including battery)
Dimension(L×W×D)(mm/inch) 175 x 130 x 45mm / 6.9 x 5.1 x1.8″
Individual packing Double blister
CPU Power supply
MT-4615 Anemometer
Air Velocity, Analog Bar Graphic, Variety of units, Air Volume,
LCD Backlight, MAX./MIN Value
Specification • Measuring air velocity
Measuring range 0.8~40m/s and air volume.
0.80~30.00 m/s, 1.40~108.00 km/h, 1.30~98.50 ft/s,
0.80~58.30 knots, 0.90~67.20 mil/h, 78~5900 ft/m, • Large LCD backlight for
±(2.0% + 50D), 30.00~40.00 m/s, 108.0~144.0 km/h, easy reading even in
Accuracy
98.50~131.20 ft/s,
58.30~77.70 knots, 67.20~90.00 mil/h, 5900~7874 dark area.
ft/m,(only for reference) • Variety of units to
Resolution 0.01m/s, 0.01km/h, 0.01 ft/s, 0.01knots, 0.01mile/h, 1ft/m choose from.
Air Velocity, m/s, km/h, mil/h, ft/m, ft/s, knots, Air • Extra functions: Max./
Unit Volume, CMS (m3/s), CMM m3/min, CFM (ft³/min), Min. value, low battery
30~40m/s only for reference
Sensor Conventional arm angle to the impeller indication,auto power
Sampling time 0.4s off, data hold.
Auto power off 10 minutes (adjustable)
Low battery indication <7V
Operation environment 0~85%RH, 0°C~40°C(no condense)
Fan Operation environment 0~95%RH, -20°C~80°C(no condense)
Storage environment 0~80%RH, -20°C~80°C(no condense)
Operating altitude Max. 2000m
Power source 9V 6F22 (not included)
Weight 154 g (not including battery)
Dimension (L×W×D)(mm/inch) 170 x 85 x 40mm / 6.7 x 3.3 x1.6″
Accessory Storage bag
Individual Packing Double blister
23